First Choice Laboratory utilizes state-of-the-art LC/MS/MS technology designed to analyze drugs present in a sample.
Shimadzu LCMS-8050 - Liquid Chromatograph Mass Spectrometer
The LCMS-8050 triple quadrupole mass spectrometer offers unparalleled measurement speeds and high-sensitivity performance.
The high performance of the LCMS-8050 defies expectations, redefining high-sensitivity, high-speed analysis. The LCMS-8050 is capable of simultaneously obtaining both qualitative and quantitative information in a single analysis. Acquisition occurs so rapidly that MS/MS scans are usable and reliable because even at 30,000 u/sec, Shimadzu uses a 0.1 u scan step.
Shimadzu LCMS-8040 – Rapid Toxicology Screening System
LCMS-8040 incorporates newly improved ion optics and collision cell technology to provide higher multiple reaction monitoring (MRM) sensitivity. These improvements also yield higher sensitivity for scan mode measurements, expanding the potential range of LC/MS/MS applications.
By incorporating newly improved ion optics and collision cell technology, the LCMS-8040 provides higher multiple reaction monitoring (MRM) sensitivity. A five-fold increase in sensitivity (reserpine, S/N ratio), as compared with that of LCMS-8030 has been achieved by improving ion focusing and minimizing ion losses between multi-pole lenses. These improvements also yield higher sensitivity for scan mode measurements. This higher sensitivity expands the potential range of LC/MS/MS applications.
The LCMS-8040 was designed to provide significantly higher sensitivity while maintaining the high speed offered by the LCMS-8030. Ultrafast MRM transition speeds, up to 555 MRMs per second, are achieved by Shimadzu's UFsweeperTM collision cell technology, proprietary high-precision quadrupole machining capabilities, and unique high voltage power supply technology. In addition, the LCMS-8040 features the fast polarity switching at 15 msec. With this high-speed performance, the LCMS-8040 can dramatically improve analytical throughput.
MRM optimization in Shimadzu's LCMS systems is based on a rapid series of automated flow injection analyses, requiring only minutes to perform. Multiple compounds can be optimized in an unattended sequence, freeing the analyst from tedious work. MRM parameters optimized for the LCMS-8030 can be transferred to the LCMS-8040, making it possible to transfer methods between systems. The LCMS-8040 offers the same ease of maintenance benefits as the LCMS-8030, and all consumables, such as desolvation lines (DL) and ESI capillaries, are interchangeable as well.
Mass SPECTROMETRY
We employ Shimadzu 8040-8050 LC/MS/MS systems: Coupling modern chromatography (separation) ts with the Fastest scanning speed possible (mass spectral analysis of the separated mixture). Modern separation science coupled to the fastest scanning speeds available, is what allows our runs to be 5 minutes with polarity switching, reference ions, retention time locking, and >12 points across each peak for the highest data quality.
The faster the scanning speeds the more points across each peak: this reduces RSDs dramatically.
[LCMS- 8050 A new state-of-the-art heated ESI probe improves desolvation efficiency to achieve trace detection and quantitation.]
This probe combines a high-temperature gas with the nebulizer spray, assisting in the desolvation of large droplets and facilitating ionization.
CHROMATOGRAPHY
We employ small particle, core shell, phase accurate analytical columns. This modern approach allows for the complete baseline separation of all isobaric compounds and all compounds elute off column in < 5 minutes.
What sets our technology apart from other labs?
Automation
Two Tecan-Evo Fully automated 11,000/day sample preparation standalone workstations: 3 arm Robotic, Fully Automated, Dispersive Solid Phase Extraction (DSPE), following inline Hydrolysis, 96WP sample preparation. DSPE provides greater cleanup and enrichment of compounds of interest while removing urea, salts, the hydrolysis enzyme, and any endogenous contaminants.
Our systems provide the highest analytical throughput possible while dramatically reducing the incidences of human error. Automation: from barcoding at accessioning, hydrolysis, IS addition, pipetting, and plate labeling to well plating increases data quality exponentially. This technological investment allows 10,000+ samples/day with increased confidence in data by eliminating errors and guaranteeing seamless expansion and high throughput day to day operation.
Analysis
Screening
[Two Olympus AU640 Chem -Analyzers for high throughput Screening The highest output with the greatest accuracy available.]
Conformation
Our analytical conformation methodology takes 5 minutes from injection to injection. This includes Barbiturates, THC, Benzos, Therapeutics, Tricyclics, Pain, and Illicit drugs including synthetics. Our methodology separates all isobaric compounds, further confirms with Ion Rations, extensive internal standards, retention time checks and a tertiary review process.
Most labs take 2-3 times longer to accomplish this. Our lab has employed the country's best analytical chemists to customize and modernize our clinical methodologies for our clients. We couple the best people to the most modern technology with the goal of proving the highest quality data. Analytical quality reduces reruns, errors, and provides doctors with information to make decisions based on analytically accurate results.